A first portion designed <br> <br> a stage lighting, stage lighting system design <br> <br> lighting design stage to follow the principle of stage art performances rules and requirements for specific configurations, it is an object of various Performing Arts The lighting process equipment needed for the reproduction process is designed and configured according to the system engineering, so that the stage lighting system can accurately and satisfactorily serve the art display.
1. Create a complete stage with free space to meet all lighting requirements;
2. In order to enable the system to continue to operate, appropriate increase in reserves and expansion of space;
3. The system's anti-jamming capability and security are important design indicators;
4. High-efficiency and energy-saving luminaires are introduced into the system design;
5. DMX512 digital signal network technology was introduced into all aspects of system design.
Second, stage lighting system process design requirements
1. The system's process design and equipment configuration have the function of using the integrated theater. In a short time, it can rotate a variety of different types of lighting operation programs.
2. The system design can be quickly switched from one lighting scheme to another lighting scheme. The conversion time is completed within 2 hours.
3. The system allows the use of all types of fixtures and other complementary equipment.
4. The system is designed with sufficient safety and storage capacity. The entire system performs continuous diagnostic checks on the main console without interrupting the main power supply.
5. The equipment in the system fully complies with the technical requirements of the stage background noise. Under the empty field conditions, the noise of all lighting devices when they are turned on and the noise of the external environment are not more than NR25, and the noise of the test point 1M effect equipment is not more than 30dB.
6. The system's expansion capability is deliberately reserved at the beginning of the system design, such as the power silicon control capacity and network capacity. When there is sufficient funds or new technologies in the future, the system will not be modified or updated in large areas due to lack of design. Reach savings and quickly adapt to changing needs.
Third, the stage lighting system description <br> <br> bit stage lighting lamps arranged a top light, area light arrays constituting the fabric, are all parts of the stage lighting spot, eliminate the dead zone, may be combined as desired flexible.
(1) The design and configuration of the top light system The top light function is to perform necessary lighting on the performance space in the depth of the stage. Various lamps used in the top light configuration greatly improve the light transmittance of the light, and the light transmittance is higher than that of the current domestic mirror. Increased by 150%, shading leaves beautifully designed, four pages set up a reasonable, shading effect is good, can be used for lighting or dyeing stage top light.
A. Configuration lamps are distributed as follows:
Over the stage, a total of 20 ceiling light booms were installed.
Each headlight uses a different number of lamps: PD-JG1501KW threaded spotlight 24 sets (with color changer), PD-JG1501KW plano spotlight set 40 (with color changer), PD-P64 (with color changer) 40 units, PH750-26 (750W) imaging spotlights 64 sets (with color changer) and (DJD) LD1000R video stage soft lights 36 sets and Caiqi 2KW moving head lights 16.
B. Arrangement and projection of lamps:
The first road surface light and the surface light are connected to the lighting lead area. When connecting, pay attention to the height of the character. You can use the first track light position as the fixed point light and place the special effect lights, and select some lights to strengthen the lighting of the fulcrum of the performance area; From Road 10 to Road 10, it can be directly shot at the stage, or it can be projected vertically downwards, which can enhance the lighting of the stage figures and landscape space. The front and rear lights converge to give the stage performance area a more uniform color and brightness.
(2) The design and configuration of the computer lamp Taking into account the intelligent lighting is the inevitable trend of stage lighting in the 21st century, in order to meet the needs of a variety of performance lighting, stage lighting design is equipped with 16 headlights of computer lights.
The computer lights are mainly arranged on the top light pole above the stage, and are controlled by DMX signals. The computer contact points are connected to the computer console through the network contacts. The lighting projection angle, brightness, conversion pattern, beam size, color and other functions can be arbitrarily adjusted to ensure that the performance is satisfied. Computer lights change requirements.
(3) Light color changer design The color changer installed on some lamps and lanterns functions as a stage light, dyeing, color change, and set off scenes to achieve a variety of effects.
Color changer configuration:
WD-512-08A series computer color changer 136 were selected.
Fourth, stage lighting control equipment configuration (1) lighting console lighting console selection of the British "Strand" company 300 series 125 light computer light console, this dimmer using quality assurance GeniusPro operating software, this software supports small and medium-sized control Station preset or tracking mode operation. The computerized light control is another standard feature of the Si Quande 300 series console. It is achieved through an intelligent mouse tracking ball.
With more than 80 years of global production, manufacturing, sales, and design experience, the reliability and advancement of its products have provided confidence for our choice and use by owners.
(2) Dimming Silicon Cabinet The dimming silicon cabinet is selected by British "Strand" company CD80-A digital dimming silicon cabinet.
The digital silicon cabinet is the carrier that realizes high power load dimming, and is also the core hardware of the dimming system. The CD80-A silicon cabinet is a dimmer with high control accuracy and high performance using digital decoding trigger control technology. Its DMX input interface uses optical isolation technology, high-precision, high-speed digital trigger system (lighting range of 1-100%, dimming curve 10, dimming precision 1024). Strong anti-interference, simple debugging, the system is not affected by temperature, voltage and other environmental effects, the system can meet the output voltage consistency requirements stipulated by the national standard first-class machine without debugging, and does not need to carry out light point, consistent maintenance and adjustment . The system adopts the ISP online system programmable large-scale integrated circuit, and the hardware reliability is improved. The software uses the "watchdog" technology and fault tolerance technology to automatically detect the distribution system even if it is strongly interfered by the external power grid and transmission line. When the electric voltage fluctuates, the triggering conduction angle can be automatically corrected to suppress the flashing of the lamp and ensure its normal operation. The silicon cabinet and the dimmer station transmit signals in a photoelectric isolation manner, which avoids the accident of burning and destroying the dimmer station due to accidental reasons such as leakage and static electricity. The silicon cabinet has the last function of the dimming memory. Once the main and sub-controls fail, they can guarantee normal performance. 9 warm-up values ​​can be set to extend the life of the lamps. The 10 dimming curves cured in the machine can fully meet the needs of various performances. There are two input interfaces for receiving both digital and analog console signals. Each power unit has a pass-through switch, and each power unit can be arbitrarily interchanged in any case, to ensure that the studio provides guarantees for live performance, shooting, live broadcast, program recording, etc. of the variety show and theatrical performance party. And for computer lights, laser effects, color-changing lights, color changer and other equipment applications to provide adequate compatibility and expansion capabilities, fully meet the needs of a variety of performances.
The second part of the stage lighting system <br> <br> an electrical design. <br> <br> power profile lighting system 2 sets of 96 digital Dimmer cabinet, 6KW192 road.
II. Security Settings for Lighting System Electrical Equipment Operation 1. Properly configure the output. Each dimming and through output is assigned by a 32A socket. The three conductors of each outlet have the same length and are twisted and output.
2. Good grounding In order to eliminate SCR interference and make the audio and video equipment meet the requirements for use, a reasonable and practical grounding system is selected in the lighting system design. Both the sound reinforcement system and the lighting system are provided with separate grounding trunks, sharing common ground, and grounding resistance ≤ 1Ω. The power cable and the lamp wire are all installed in the wire trough, and the wire trough is provided with a good grounding device.
3. Electric shock protection As most of the lighting distribution lines are connected to the stage lighting through the socket, according to the conventional method of the low-voltage power distribution system, the leakage protection should be installed for indirect contact protection. Because the leakage switch is easy to malfunction, it directly affects the stage lighting system. The reliability is therefore based on the way we use the PE wire and the relevant circuit phase wiring together. In order to reduce the zero-sequence impedance and ensure that the single-phase ground fault occurs, the protective device can reliably act to ensure personal safety.
4. Lightning Protection Lightning arresters are installed in substations of substations and surge protection devices are installed in the light distribution cabinets to prevent overcurrents caused by electromagnetic induction and electrostatic induction when lightning strikes on the stage of a cultural arts center or nearby buildings. Voltage, damage to the dimmer cabinet and lighting control computer system, to ensure the safety of the dimming silicon cabinet and lighting control computing system.
Third, the lighting system electrical cables and wiring laying settings 1. The output cable from the cabinet to all the outlets of the socket are all of the same length and the output is twisted. Lamp lines and audio and video signal lines are far away from each other and must intersect at 90° when they meet. There is a distance of 0.5M. If it is impossible to avoid parallelism, the spacing should be greater than 1M.
2. All signal connection cables use five-core shielded cable to prevent interference.
3. There is an independent grounding line. The power cable and the lamp line should be installed in the metal slot. The metal slot should be grounded.
4. The separation between strong and weak electricity in the socket box is separated by metal separators to avoid the interference of strong electricity to weak electricity and ensure the safety of the weak electricity system.
5. Low-smoke (LSF), flame-retardant PVC type copper core cables should be capable of long-term operation at 90°C. Under normal use conditions, the cable life should be more than 30 years.
6. The socket box adopts the internationally advanced products produced by “national standard†enterprises. The strong and weak electricity in the insert box is separated by metal partitions to ensure safety and electromagnetic compatibility.
7. The cable tray uses thermal cables for fire detection to prevent cable fires.
8. The bridge or trunking is covered and fireproofed. The type, voltage, current-carrying capacity, cross-section, number of cores, sheathing, etc. of the power cable and control cable shall meet the requirements of the circuit type, transmission model, use environment, and laying method, and comply with relevant specifications.
9. The control and power cables of the moving parts adopt flexible cables that meet the fire protection requirements. The laying of cables shall comply with the requirements of GB50258-96 "Electrical Installation Installation Project 1KV and Below Construction Inspection and Acceptance Specifications".
10. Electromagnetic interference should be minimized when laying cables. When using a cable hose, its length cannot exceed 1 meter. Suspended or sagging flexible cables for power or control lines shall be provided with stress relief central cores, which shall be clamped at both ends in order to relieve stress on the conductors.
11. The cores of multi-core and shielded cables used for power or control circuits are easy to identify by number. Color codes are used for cables of less than 25 cores. The number of cable cores is not identified by the type of cable laying or sequence.
12. The cable numbers at both ends of each power and control cable are the same and are marked with a unique number. The cable number is shown in the wiring diagram.
13. The cable shall have a sufficient length of cable to meet the requirements of the total travel of the equipment, including the required travel to the maintenance position. All cable entry devices have appropriate cable entries for cable replacement. The remaining cable should be wrapped around the cable tray or inside the device and firmly secured.
14. When the box is installed, it should be aligned perpendicular to the wall surface, the vertical deviation is not more than 2mm, the inlet and outlet box is arranged neatly, and there is an appropriate margin. Pipes with different loops, different voltages, and AC-DC conductors that are threaded in the pipe shall not penetrate the same pipe. The conductor shall not have joints and twists in the pipe. The conductor shall penetrate into the pipe and be sheathed at the outlet to protect the conductor. Before laying the cables, carefully inspect the cables for mechanical damage and perform insulation shake measurements. Power and lighting distribution box installation, its quality standards in line with national electrical engineering construction specifications. The floor power distribution box is firmly mounted on angle steel or channel steel, fixed with screws and grounded. The inlet and outlet pipes are about 10 cm above the base in the foundation. The dimensions of the installation position are shown in the paper, and the installation of the access door behind the wall is not required. The floor-type power distribution box is installed with a verticality of 1.5 mm per meter and the disk is 2 mm indirect. The lighting box is generally wall-mounted. This project adopts two kinds of light and dark installations. The concealed wall-mounted distribution box is directly installed in the wall when the wall is built, or a hole can be reserved on the wall and then installed. Ensure that the installation is firm, and the grounding is good. The installation of the flat, positive, and the size meets the design requirements. The bottom edge is 1.5M from the ground, and the vertical deviation of the lighting distribution box is not more than 3mm. The piping to and from the distribution box is allocated to the distribution box and used as a cap. Secure with lock nut. The distribution box is installed with the cover plate surface being the same as the stucco layer, and the pipelines entering and exiting the box are concealed.
IV. Installation of lighting electrical equipment cabinets 1. The cabinets and racks of structural electrical equipment are made of metal and steel plates that are treated with anti-embroidering. If necessary, they are reinforced with steel plates or steel racks. Electrical equipment cabinets are protected against dust and moisture. All cabinets and racks are completely closed except for ventilation and cable access. The depth of each cabinet guarantees proper equipment and wiring space. The depth, height, and color of each cabinet in each specific group are the same.
2. Ventilation All electrical components or devices can operate continuously in the enclosures used and in the specified environment. The cabinet has proper natural passage. To disperse the heat generated by the equipment, use fine mesh or foam grille protection through the mouth to prevent debris from entering. The housing should be pressurized and the inlet air must be drained.
3. The cable inlet and outlet cable holes are reserved at the factory according to the desired location; and a removable plate is provided for final processing at the site. Consider the cable's outer diameter, laying method and sufficient bending radius at the cable entry and exit line, and there is a cable fixing device.
4. Enclosure Doors and Access Panel Doors and panels are designed to be rigid enough that the doors and panels can be removed and overhauled, and panels are fitted with dust seals. All shells and panels are painted dry after thoroughly removing grease and rust.
5. The mark of the parts in the signage equipment cabinet shall also be a permanent mark. Temporary paste marks or pen identification marks shall not be used. The size of the nameplate and the logo are large enough. Under the normal light, the nameplate and logo can be seen at a distance of 2 meters.
6. Information bag A material kit is attached to the inside of the main door of each cabinet shell and is used to load data or drawings of each electrical component or device sample, wiring, maintenance, and maintenance of the electrical equipment cabinet.
5. Requirements for design and construction of silicon cabinets 1. Design requirements (1) Since the thyristor will emit a large amount of heat during its work, in order to ensure the normal operation of silicon, the silicon chamber must be equipped with a separate air conditioning system and ventilation equipment.
(2) There is a No. 10 channel base under the thyristor, power supply cabinet and field light cabinet.
(3) The height of the antistatic floor in the silicon room is 300mm.
(4) The floor load of the dimming distribution room is 800Kg/m2.
(5) See the construction drawing for the dimensions of the cable bridge through the floor and walls.
(6) Refractory materials shall be used for fireproofing of all holes after the cable tray is laid.
1. Create a complete stage with free space to meet all lighting requirements;
2. In order to enable the system to continue to operate, appropriate increase in reserves and expansion of space;
3. The system's anti-jamming capability and security are important design indicators;
4. High-efficiency and energy-saving luminaires are introduced into the system design;
5. DMX512 digital signal network technology was introduced into all aspects of system design.
Second, stage lighting system process design requirements
1. The system's process design and equipment configuration have the function of using the integrated theater. In a short time, it can rotate a variety of different types of lighting operation programs.
2. The system design can be quickly switched from one lighting scheme to another lighting scheme. The conversion time is completed within 2 hours.
3. The system allows the use of all types of fixtures and other complementary equipment.
4. The system is designed with sufficient safety and storage capacity. The entire system performs continuous diagnostic checks on the main console without interrupting the main power supply.
5. The equipment in the system fully complies with the technical requirements of the stage background noise. Under the empty field conditions, the noise of all lighting devices when they are turned on and the noise of the external environment are not more than NR25, and the noise of the test point 1M effect equipment is not more than 30dB.
6. The system's expansion capability is deliberately reserved at the beginning of the system design, such as the power silicon control capacity and network capacity. When there is sufficient funds or new technologies in the future, the system will not be modified or updated in large areas due to lack of design. Reach savings and quickly adapt to changing needs.
Third, the stage lighting system description <br> <br> bit stage lighting lamps arranged a top light, area light arrays constituting the fabric, are all parts of the stage lighting spot, eliminate the dead zone, may be combined as desired flexible.
(1) The design and configuration of the top light system The top light function is to perform necessary lighting on the performance space in the depth of the stage. Various lamps used in the top light configuration greatly improve the light transmittance of the light, and the light transmittance is higher than that of the current domestic mirror. Increased by 150%, shading leaves beautifully designed, four pages set up a reasonable, shading effect is good, can be used for lighting or dyeing stage top light.
A. Configuration lamps are distributed as follows:
Over the stage, a total of 20 ceiling light booms were installed.
Each headlight uses a different number of lamps: PD-JG1501KW threaded spotlight 24 sets (with color changer), PD-JG1501KW plano spotlight set 40 (with color changer), PD-P64 (with color changer) 40 units, PH750-26 (750W) imaging spotlights 64 sets (with color changer) and (DJD) LD1000R video stage soft lights 36 sets and Caiqi 2KW moving head lights 16.
B. Arrangement and projection of lamps:
The first road surface light and the surface light are connected to the lighting lead area. When connecting, pay attention to the height of the character. You can use the first track light position as the fixed point light and place the special effect lights, and select some lights to strengthen the lighting of the fulcrum of the performance area; From Road 10 to Road 10, it can be directly shot at the stage, or it can be projected vertically downwards, which can enhance the lighting of the stage figures and landscape space. The front and rear lights converge to give the stage performance area a more uniform color and brightness.
(2) The design and configuration of the computer lamp Taking into account the intelligent lighting is the inevitable trend of stage lighting in the 21st century, in order to meet the needs of a variety of performance lighting, stage lighting design is equipped with 16 headlights of computer lights.
The computer lights are mainly arranged on the top light pole above the stage, and are controlled by DMX signals. The computer contact points are connected to the computer console through the network contacts. The lighting projection angle, brightness, conversion pattern, beam size, color and other functions can be arbitrarily adjusted to ensure that the performance is satisfied. Computer lights change requirements.
(3) Light color changer design The color changer installed on some lamps and lanterns functions as a stage light, dyeing, color change, and set off scenes to achieve a variety of effects.
Color changer configuration:
WD-512-08A series computer color changer 136 were selected.
Fourth, stage lighting control equipment configuration (1) lighting console lighting console selection of the British "Strand" company 300 series 125 light computer light console, this dimmer using quality assurance GeniusPro operating software, this software supports small and medium-sized control Station preset or tracking mode operation. The computerized light control is another standard feature of the Si Quande 300 series console. It is achieved through an intelligent mouse tracking ball.
With more than 80 years of global production, manufacturing, sales, and design experience, the reliability and advancement of its products have provided confidence for our choice and use by owners.
(2) Dimming Silicon Cabinet The dimming silicon cabinet is selected by British "Strand" company CD80-A digital dimming silicon cabinet.
The digital silicon cabinet is the carrier that realizes high power load dimming, and is also the core hardware of the dimming system. The CD80-A silicon cabinet is a dimmer with high control accuracy and high performance using digital decoding trigger control technology. Its DMX input interface uses optical isolation technology, high-precision, high-speed digital trigger system (lighting range of 1-100%, dimming curve 10, dimming precision 1024). Strong anti-interference, simple debugging, the system is not affected by temperature, voltage and other environmental effects, the system can meet the output voltage consistency requirements stipulated by the national standard first-class machine without debugging, and does not need to carry out light point, consistent maintenance and adjustment . The system adopts the ISP online system programmable large-scale integrated circuit, and the hardware reliability is improved. The software uses the "watchdog" technology and fault tolerance technology to automatically detect the distribution system even if it is strongly interfered by the external power grid and transmission line. When the electric voltage fluctuates, the triggering conduction angle can be automatically corrected to suppress the flashing of the lamp and ensure its normal operation. The silicon cabinet and the dimmer station transmit signals in a photoelectric isolation manner, which avoids the accident of burning and destroying the dimmer station due to accidental reasons such as leakage and static electricity. The silicon cabinet has the last function of the dimming memory. Once the main and sub-controls fail, they can guarantee normal performance. 9 warm-up values ​​can be set to extend the life of the lamps. The 10 dimming curves cured in the machine can fully meet the needs of various performances. There are two input interfaces for receiving both digital and analog console signals. Each power unit has a pass-through switch, and each power unit can be arbitrarily interchanged in any case, to ensure that the studio provides guarantees for live performance, shooting, live broadcast, program recording, etc. of the variety show and theatrical performance party. And for computer lights, laser effects, color-changing lights, color changer and other equipment applications to provide adequate compatibility and expansion capabilities, fully meet the needs of a variety of performances.
The second part of the stage lighting system <br> <br> an electrical design. <br> <br> power profile lighting system 2 sets of 96 digital Dimmer cabinet, 6KW192 road.
II. Security Settings for Lighting System Electrical Equipment Operation 1. Properly configure the output. Each dimming and through output is assigned by a 32A socket. The three conductors of each outlet have the same length and are twisted and output.
2. Good grounding In order to eliminate SCR interference and make the audio and video equipment meet the requirements for use, a reasonable and practical grounding system is selected in the lighting system design. Both the sound reinforcement system and the lighting system are provided with separate grounding trunks, sharing common ground, and grounding resistance ≤ 1Ω. The power cable and the lamp wire are all installed in the wire trough, and the wire trough is provided with a good grounding device.
3. Electric shock protection As most of the lighting distribution lines are connected to the stage lighting through the socket, according to the conventional method of the low-voltage power distribution system, the leakage protection should be installed for indirect contact protection. Because the leakage switch is easy to malfunction, it directly affects the stage lighting system. The reliability is therefore based on the way we use the PE wire and the relevant circuit phase wiring together. In order to reduce the zero-sequence impedance and ensure that the single-phase ground fault occurs, the protective device can reliably act to ensure personal safety.
4. Lightning Protection Lightning arresters are installed in substations of substations and surge protection devices are installed in the light distribution cabinets to prevent overcurrents caused by electromagnetic induction and electrostatic induction when lightning strikes on the stage of a cultural arts center or nearby buildings. Voltage, damage to the dimmer cabinet and lighting control computer system, to ensure the safety of the dimming silicon cabinet and lighting control computing system.
Third, the lighting system electrical cables and wiring laying settings 1. The output cable from the cabinet to all the outlets of the socket are all of the same length and the output is twisted. Lamp lines and audio and video signal lines are far away from each other and must intersect at 90° when they meet. There is a distance of 0.5M. If it is impossible to avoid parallelism, the spacing should be greater than 1M.
2. All signal connection cables use five-core shielded cable to prevent interference.
3. There is an independent grounding line. The power cable and the lamp line should be installed in the metal slot. The metal slot should be grounded.
4. The separation between strong and weak electricity in the socket box is separated by metal separators to avoid the interference of strong electricity to weak electricity and ensure the safety of the weak electricity system.
5. Low-smoke (LSF), flame-retardant PVC type copper core cables should be capable of long-term operation at 90°C. Under normal use conditions, the cable life should be more than 30 years.
6. The socket box adopts the internationally advanced products produced by “national standard†enterprises. The strong and weak electricity in the insert box is separated by metal partitions to ensure safety and electromagnetic compatibility.
7. The cable tray uses thermal cables for fire detection to prevent cable fires.
8. The bridge or trunking is covered and fireproofed. The type, voltage, current-carrying capacity, cross-section, number of cores, sheathing, etc. of the power cable and control cable shall meet the requirements of the circuit type, transmission model, use environment, and laying method, and comply with relevant specifications.
9. The control and power cables of the moving parts adopt flexible cables that meet the fire protection requirements. The laying of cables shall comply with the requirements of GB50258-96 "Electrical Installation Installation Project 1KV and Below Construction Inspection and Acceptance Specifications".
10. Electromagnetic interference should be minimized when laying cables. When using a cable hose, its length cannot exceed 1 meter. Suspended or sagging flexible cables for power or control lines shall be provided with stress relief central cores, which shall be clamped at both ends in order to relieve stress on the conductors.
11. The cores of multi-core and shielded cables used for power or control circuits are easy to identify by number. Color codes are used for cables of less than 25 cores. The number of cable cores is not identified by the type of cable laying or sequence.
12. The cable numbers at both ends of each power and control cable are the same and are marked with a unique number. The cable number is shown in the wiring diagram.
13. The cable shall have a sufficient length of cable to meet the requirements of the total travel of the equipment, including the required travel to the maintenance position. All cable entry devices have appropriate cable entries for cable replacement. The remaining cable should be wrapped around the cable tray or inside the device and firmly secured.
14. When the box is installed, it should be aligned perpendicular to the wall surface, the vertical deviation is not more than 2mm, the inlet and outlet box is arranged neatly, and there is an appropriate margin. Pipes with different loops, different voltages, and AC-DC conductors that are threaded in the pipe shall not penetrate the same pipe. The conductor shall not have joints and twists in the pipe. The conductor shall penetrate into the pipe and be sheathed at the outlet to protect the conductor. Before laying the cables, carefully inspect the cables for mechanical damage and perform insulation shake measurements. Power and lighting distribution box installation, its quality standards in line with national electrical engineering construction specifications. The floor power distribution box is firmly mounted on angle steel or channel steel, fixed with screws and grounded. The inlet and outlet pipes are about 10 cm above the base in the foundation. The dimensions of the installation position are shown in the paper, and the installation of the access door behind the wall is not required. The floor-type power distribution box is installed with a verticality of 1.5 mm per meter and the disk is 2 mm indirect. The lighting box is generally wall-mounted. This project adopts two kinds of light and dark installations. The concealed wall-mounted distribution box is directly installed in the wall when the wall is built, or a hole can be reserved on the wall and then installed. Ensure that the installation is firm, and the grounding is good. The installation of the flat, positive, and the size meets the design requirements. The bottom edge is 1.5M from the ground, and the vertical deviation of the lighting distribution box is not more than 3mm. The piping to and from the distribution box is allocated to the distribution box and used as a cap. Secure with lock nut. The distribution box is installed with the cover plate surface being the same as the stucco layer, and the pipelines entering and exiting the box are concealed.
IV. Installation of lighting electrical equipment cabinets 1. The cabinets and racks of structural electrical equipment are made of metal and steel plates that are treated with anti-embroidering. If necessary, they are reinforced with steel plates or steel racks. Electrical equipment cabinets are protected against dust and moisture. All cabinets and racks are completely closed except for ventilation and cable access. The depth of each cabinet guarantees proper equipment and wiring space. The depth, height, and color of each cabinet in each specific group are the same.
2. Ventilation All electrical components or devices can operate continuously in the enclosures used and in the specified environment. The cabinet has proper natural passage. To disperse the heat generated by the equipment, use fine mesh or foam grille protection through the mouth to prevent debris from entering. The housing should be pressurized and the inlet air must be drained.
3. The cable inlet and outlet cable holes are reserved at the factory according to the desired location; and a removable plate is provided for final processing at the site. Consider the cable's outer diameter, laying method and sufficient bending radius at the cable entry and exit line, and there is a cable fixing device.
4. Enclosure Doors and Access Panel Doors and panels are designed to be rigid enough that the doors and panels can be removed and overhauled, and panels are fitted with dust seals. All shells and panels are painted dry after thoroughly removing grease and rust.
5. The mark of the parts in the signage equipment cabinet shall also be a permanent mark. Temporary paste marks or pen identification marks shall not be used. The size of the nameplate and the logo are large enough. Under the normal light, the nameplate and logo can be seen at a distance of 2 meters.
6. Information bag A material kit is attached to the inside of the main door of each cabinet shell and is used to load data or drawings of each electrical component or device sample, wiring, maintenance, and maintenance of the electrical equipment cabinet.
5. Requirements for design and construction of silicon cabinets 1. Design requirements (1) Since the thyristor will emit a large amount of heat during its work, in order to ensure the normal operation of silicon, the silicon chamber must be equipped with a separate air conditioning system and ventilation equipment.
(2) There is a No. 10 channel base under the thyristor, power supply cabinet and field light cabinet.
(3) The height of the antistatic floor in the silicon room is 300mm.
(4) The floor load of the dimming distribution room is 800Kg/m2.
(5) See the construction drawing for the dimensions of the cable bridge through the floor and walls.
(6) Refractory materials shall be used for fireproofing of all holes after the cable tray is laid.
Industrial sectional High Speed Overhead Door
Product Description
Electric Overhead Sliding Door For Logistic
Product Description:
choose your glass:
The glass can be use polycarbonate glass( clear or frosted )
and tempered glass (clear or frosted/coated colour /tinted color/mirrow)
5-10mm thickness for glass
>>Tempered Glass - enhanced safety
>>Polycarbonate - superior strength with UV protection
hardware Accessories



Product Description:
Name | Sectional overhead glass panel garage door | |
Operation way | electric /remote/manual | |
Position | garage/shop/auto4S store/Industrial/Garden etc. | |
Door panel structure |
aluminum alloy frame +Tempered Glass / Polycarbonate Glass /double-glazing |
|
Door panel frame |
material | aluminum alloy |
thickness | 2.0mm | |
color |
white, black ,gray, silver gray, wood grain, cream (any colours can be specified) |
|
surface Treating | baking varnish | |
Thickness of door panel |
40mm/50mm |
|
Core of the door panel |
Tempered Glass |
5.0`6.0mm thickness ,Full view clear or frosted |
Polycarbonate Glass |
5.0mm ~10mm thickness ,Full view clear or frosted |
|
aluminium sheet |
9.0mm in thickness,baking varnish with surface traeting,color like the frame |
|
other tempered Glass |
mirror glass,baking glass and many kind of glass for your options |
choose your glass:
The glass can be use polycarbonate glass( clear or frosted )
and tempered glass (clear or frosted/coated colour /tinted color/mirrow)
5-10mm thickness for glass
>>Tempered Glass - enhanced safety
>>Polycarbonate - superior strength with UV protection
hardware Accessories
Guide rail |
Size | 2"/3" |
Materail | galvanized steel | |
Thickness | 2.0mm | |
Bracket | Materail | galvanized steel |
Thickness | 3.0mm | |
Hinge | Model | Finger-protect/normal |
Materail | galvanized steel | |
Thickness | 3.0mm | |
Roller | Size | 2"/3" |
Materail | galvanized steel/Nylon | |
shaft | Model | solid/hollow |
Materail | galvanized steel | |
External key lock | For independent garage door, this sort of lock allows you to use external key to start the clutch deviceand open the door in case of power failure under the condition that there are no entries or side doors. | |
Box airbag safety system |
The door will be automatically to rise If there are any obstacles in the process of downward |
|
Spring break device |
When the spring is broken,the door can auto stop to prevent the door falling down |
|
Cable break safety system |
Once the cable is broken ,this device will blocked on the guide rails in case of breakage of the steel wire prevent the door falling down | |
V external reinforcing bars |
helping to enhance the strength of door panels,1.0mm thickness, 80mm height, with the bars the door can against the Hurricane |




overhead sectional door , sliding door , industrial overhead door,automatic industrial doors , industrial sectional door,industrial sectional overhead door
SHENZHEN HONGFA AUTOMATIC DOOR CO., LTD , https://www.hongfafd.com